home
WelcomePublicationsContact
 

"Treatment Effect of Balloon Pulmonary Angioplasty in CTEPH Quantified by Automatic Comparative Imaging in CTPA"

Zhiwei Zhai, Hideki Ota, Marius Staring, Jan Stolk, Koichiro Sugimura, Kei Takase and Berend C. Stoel

Abstract

Purpose: Balloon pulmonary angioplasty (BPA) in patients with inoperable chronic thromboembolic pulmonary hypertension (CTEPH) can have variable outcomes. To gain more insight into this variation, we aimed to visualize and quantify changes in lung perfusion using CT pulmonary angiography (CTPA). We validated these measurements of perfusional changes against hemodynamic changes measured during right-heart catheterization.

Materials and Methods: We studied 14 consecutive CTEPH patients (12 female; age: 65±17), who underwent CTPA and right-heart catheterization, before and after BPA. Post-treatment images were registered to pre-treatment CT scans (using the Elastix toolbox) to obtain corresponding locations. Pulmonary vascular trees and their centerlines were detected using a graph-cuts method and distance transform. Areas distal from vessels were defined for measuring perfusional changes in the parenchyma. Subsequently, the density changes within the vascular and parenchymal areas were calculated and corrected for inspiration level differences, and displayed in color-coded overlays. For quantification, the median and inter-quartile range (IQR) of the density changes were calculated in the vascular and parenchymal areas (ΔVD and ΔPD, respectively). The recorded changes in hemodynamic parameters included changes in systolic, diastolic and mean pulmonary artery pressure (ΔsPAP, ΔdPAP and ΔmPAP, respectively) and in vascular resistance (ΔPVR). The Spearman’s correlation coefficients between perfusional changes and hemodynamic changes were tested.

Results: PAP and PVR were significantly improved after BPA. Comparative imaging maps showed distinct patterns in perfusional changes between patients. Within vessels, the IQR of ΔVD correlated with ΔsPAP (R=-0.58, p=0.03), ΔdPAP (R=-0.71, p=0.005), ΔmPAP (R=-0.71, p=0.005) and ΔPVR (R=-0.77, p=0.001, see Figure). In the parenchyma, the median of ΔPD correlated with ΔdPAP (R=-0.71, p=0.005) and ΔmPAP (R=-0.68, p =0.008).

Conclusion: Comparative imaging in CTEPH patients offers insight into differences in BPA treatment effect. Quantification of these perfusional changes provides non-invasive measures that reflect hemodynamic changes.

 

Download

PDF (2 pages, 1072 kB) click to start download

Copyright © 2017 by the authors. Published version © 2017 by . Personal use of this material is permitted. However, permission to reprint or republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works, must be obtained from the copyright holder.

 

BibTeX entry

@inproceedings{Zhai:2017,
author = {Zhai, Zhiwei and Ota, Hideki and Staring, Marius and Stolk, Jan and Sugimura, Koichiro and Takase, Kei and Stoel, Berend C.},
title = {Treatment Effect of Balloon Pulmonary Angioplasty in CTEPH Quantified by Automatic Comparative Imaging in CTPA},
booktitle = {RSNA},
address = {Chicago, USA},
month = {November},
year = {2017},
}

last modified: 11-05-2020 |webmaster |Copyright 2004-2024 © by Marius Staring